Configuration
Scroll down or click for Installer Setup Options (ISU)
Set Time and Date
During installation the thermostat will already have the year flashing once you select ON DEVICE.
NOTE: Time and date are set automatically when the customer registers the thermostat to a First Alert account.
Time
-
Press MENU on the thermostat
-
Press ↑ or ↓ to go to TIME and press SELECT
-
Press ↑ or ↓ to choose 12 or 24 hour clock format and press NEXT
-
Press ↑ or ↓ to adjust the hour and press NEXT.
-
Press ↑ or ↓ to adjust the minute and press SAVE & EXIT.
Date
-
Press MENU on the thermostat.
-
Press ↑ or ↓ to go to DATE and press SELECT.
-
Press ↑ or ↓ to choose YEAR and press NEXT.
-
Press ↑ or ↓ to choose MONTH and press NEXT.
-
Press ↑ or ↓ to choose DATE and press SAVE & EXIT.
System Setup
On initial setup the thermostat will enter the ISU menu. If entering the ISU menu after initial setup, follow the steps below:
-
Press and hold the bottom left button and Up arrow ↑ button for 5 seconds to access the INSTALLER SETUP
-
The display shows the ISU number on the left and the ISU setting on the right.
When an ISU number is displayed, press ↑ or ↓ to change the setting for that ISU.
-
After choosing the correct setting for an ISU, press NEXT to advance to the next ISU setting.
-
To finish setup, press the SAVE & EXIT button; this will save your settings and return to the Home screen.
Installer Setup Options (ISU)
Note: Depending on system settings, not all options may be available.
|
# ISU |
ISU Name |
ISU Options (factory defaults are bold) |
||||
|---|---|---|---|---|---|---|
|
1040 |
Scheduling Options (If you do not wish to set a schedule, use the default setting, then enter the Schedule Menu after completing setup and select Off) |
1 = 1 week (all days the same) 2 = 5-2 Programmable (separate weekdays and weekend) 3 = 5-1-1 Programmable (separate Saturday and Sunday) 4 = 7-Day Programmable (each day separate) |
||||
|
1050 |
Temperature Indication Scale |
|
||||
|
2000 |
Heating System Type |
1 = Conventional Forced Air Heat 2 = Heat Pump 3 = Radiant Heat (Boiler) 5 = None (Cool Only) |
||||
|
If you are unsure what type of system you have, refer to your heating/cooling system equipment literature or call an HVAC professional. If you select the wrong system type, the thermostat will not operate the equipment as intended. |
||||||
|
2010 |
Heating Equipment Type |
Conventional Forced Air Heat: 1 = Standard Efficiency Gas Forced Air 2 = High Efficiency Gas Forced Air 3 = Oil Forced Air 4 = Electric Forced Air 5 = Hot Water Fan Coil
(ISU 2010 not shown when 2000 = Heat Pump)
Radiant Heat: 9 = Hot Water Radiant Heat 12 = Steam |
||||
|
2060 |
Reversing Valve Polarity |
0 = O (O/B on Cool. O wire is connected to the O/B terminal and controls cooling.) 1 = B (O/B on Heat. B wire is connected to the O/B terminal and controls heat.) The literature that came with your heat pump equipment should indicate whether the reversing valve is energized in Heat or Cool mode. |
||||
|
2070 |
Cool / Compressor Stages |
0, 1, 2 Select the number of Stages. For heat pumps, only 1 stage is supported. |
||||
|
2071 |
Heat / Backup Heat Stages |
Heat Stages: 1, 2 Backup Heat Stages: 0, 1 |
||||
|
2180 |
Aux Backup Heat Type (for Heat Pump Systems) |
31=Electric Forced Air (This thermostat only supports electric backup heat. If your heat pump uses a gas or oil backup heat source, this thermostat should not be used.) |
||||
|
3000 |
Auto Changeover |
0 = Hidden (Manual only) 1 = Enabled (Automatic available. In Auto mode, the thermostat automatically switches between heating and cooling to maintain the desired indoor temperature. This option is not recommended if the outdoor temperature often stays below 50°F [10°C] during winter months.) |
||||
|
4090 |
Smart Response |
0=No 1=Yes (Smart Response is a comfort setting. Heating or cooling equipment will turn on earlier, ensuring the indoor temperature will match the setpoint at the scheduled time.) |
||||
|
4103 |
Minimum Heat Setpoint |
32 °F to 50 °F (Default is 40 °F) 0 °C to 10.0 °C (Default is 4.5 °C) Do not set this lower than 40°F/4.5°C unless installed in a location where pipes are not at risk of freezing. |
||||
|
7110 |
Air Filter Replacement Reminder (Run Time only counts the time that Heat, Cool or Fan are running) |
|
||||
|
14003 |
Backlighting |
0 = On Demand 1 = Continuous |
||||
|
14004 |
Backlight brightness |
1 - 5 (Only displayed if Continuous Backlight selected.) |
||||
|
14005 |
Idle screen selection |
0 - Minimum Information shown 1 - Setpoint shown on Idle screen 2 - Maximum display information shown |
||||
|
14006 |
Idle screen message center (Only available if Settings 0 or 1 are selected in 14005). |
|
||||
|
14007 |
Home screen message center |
|
||||
|
14010 |
Clock format |
12/24 |
||||
|
14015 |
Daylight Saving Time |
0 = Off 1 = On |
||||